BPDMH - C80, ELECTRO-WASH

  • MSDS: BPDMH
  • Manufacturer: CHEMTRONICS INC
  • Product Name: C80, ELECTRO-WASH
  • National Stock Number: 6850-00N030044
Product Identification

Product ID:C80, ELECTRO-WASH
MSDS Date:06/01/1987
FSC:6850
NIIN:00N030044
MSDS Number: BPDMH

Responsible Party
CHEMTRONICS INC
8125 COBB CENTER DR
KENNESAW, GA 30144
US

Emergency Phone: 404-424-4888

Info Phone: 404-424-4888

Preparer: S. H. STEIN

Cage: 2M589

Contractor
CHEMTRONICS INC (CANCELLED USE 21267)
HAUPPAUGE, NY 11760 US

Telephone: 770-424-4888/800-645-5244

Cage: 2M589

Ingredients

ETHANE, 1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 20-50%

OSHA PEL 1000 PPM;1250 STEL

ACGIH TLV: 1000 PPM;1250 STEL


METHANE, TRICHLOROFLUORO-; (TRICHLOROFLUOROMETHANE)

CAS: 75-69-4

RTECS: PB6125000

Fraction By Weight: 50-70%

OSHA PEL 1000 PPM

ACGIH TLV: C, 1000 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CARBON DIOXIDE; (CARBON DIOXIDE PROPELLANT)

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 3%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93


INGEST OF TRICHLOROTRIFLUOROETHANE IS TO BE

RTECS: 9999999ZZ


IF NEC. DO NOT INDUCE VOMIT AS HAZ OF

RTECS: 9999999ZZ


IT TO PROGRESS THRU INTESTINAL TRACT. NOTE TO MD

RTECS: 9999999ZZ


DYSRYTHMIAS, CATECHOLAMINE DRUGS, SUCH AS

RTECS: 9999999ZZ


THREATENING EMERGENCIES.

RTECS: 9999999ZZ


MECHANICAL VENTILATION SHOULD BE USED IN LOW PLACES.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 1
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFC) MATLS HAVE
PRDCED SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT F OR LIFE-SUSTAINING
USES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO CFC'S .(EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INHAL: VAP IS HVR THAN AIR & CAN CAUSE
SUFFOCATION BY REDUCING O*2 AVAIL FOR BRTHG. BRTHG HIGH CONC OF
PRODS CAN CAUSE LIGHT-HEADEDNESS, GIDDINESS, SHORTNESS OF BRTH &
MAY LEAD TO NARCOSIS, C ARDIAC IRREGULARITIES, UNCON/DEATH. SKIN:
NOT A CORR/IRRITANT AFTER SINGLE CONT. HOWEVER, RPTD LIQ CONT CAN
(SUPP DATA)
Medical Cond Aggravated by Exposure:CARDIOVASCULAR DISEASE.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR, CALL MD. IF NOT BRTHG, GIVE ARTF
RESP, PREF MOUTH-TO-MOUTH. IF BRTHG DFCULT, GIVE O*2. DO NOT GIVE
EPINEPHRINE/SIMILAR DRUGS. EYE: IMMED FLUSH W/PLENTY OF WATER FOR
AT LEAS T 15 MIN. CALL MD. SKIN: FLUSH W/WATER.GET MD ATTN IF IRRIT
IS PRESENT. INGEST:NO SPECIFIC INTERVENTION IS INDICATED AS CMPND
IS NOT LIKELY TO BE HAZARDOUS BY INGEST. HOWEVER, CONSULT MD (ING
5)

Fire Fighting

Flash Point Method:TOC
Flash Point:NONE
Extinguishing Media:NONFLAMMABLE. USE MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP .
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCLUDE HCL &
PHOSGENE . PRESSURIZED AEROSOL CNTNRS AT ELEVATED TEMPS MAY VENT,
RUPTURE/BURST & ADD TO FLYING & (SUPP DATA)

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE OPEN FLAMES OR RED HOT
SURFACES. ALLOW TO EVAPORATE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE NEAR SOURCES OF HEAT, IN
DIRECT SUNLIGHT/WHERE TEMPS EXCEED 120F. DO NOT PUNCTURE/DAM
CNTNRS. ROTATE STOCK.USE ONLY IN WELL-VENTD AREA.
Other Precautions:NO SMOKING IN AREA OF USE.DO NOT USE IN GEN VICINITY
OF ARC WELDING, OPEN FLAMES/HOT SURFS.HEAT &/UV RADIATION MAY CAUSE
FORMATION OF HCL &/PHOSGENE . DO NOT SPRAY LIQ ON SKIN. AVOID BRTHG
VAPS & PRLNGD SKIN EXPOSURE.

Exposure Controls

Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING PROD. NIOSH/MSHA
APPROVED SCBA IS REQUIRED IF A LARGE SPILL OCCURS.
Ventilation:NORM VENT FOR STANDARD MFG PROCEDURES IS GENERALLY ADEQ.LOC
EXHST SHLD BE USED WHEN LG AMTS ARE RELEASED. (ING 9)
Protective Gloves:BUTYL GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:FALLING DEBRIS. DECOMP MAY OCCUR. HAZ DECOMP:HYDROCHLORIC &
HYDROFLUORIC ACIDS, POSSIBLY CARBONYL HALIDES.HLTH HAZ:CAUSE DEFAT
OF SKIN RSLTG IN IRRIT. MATL IS POORLY ABSORBED THRU SKIN. EYE:
LIQ CONT CAN CAUSE DISCOMFORT, USUALLYNO EXTENDED EFT. INGEST:
ALTHOUGH ORAL TOX IS LOW (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:>75F,>24C
Vapor Pres:334 @ 77F
Vapor Density:4.6 @ 77F
Spec Gravity:1.46 @ 77F
pH:NEUT
Evaporation Rate & Reference:1 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR COLORLESS LIQUID; FAINT SOLVENT ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS - POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:AVOID SPRAYING NEAR OPEN FLAMES OR RED HOT
SURFACES. DO NOT HEAT AEROSOL CONTAINERS ABOVE 49C/120F.
Hazardous Decomposition Products:HCL, PHOSGENE .CMPD CAN BE DECOMPOSED
BY HIGH TEMP (OPEN FLAMES, GLOWING METAL SURFS, ETC.) FORMING (SUPP
DATA)

Disposal

Waste Disposal Methods:ALLOW TO EVAPORATE. DO NOT PUNCTURE OR
INCINERATE AEROSOL CANS. COMPLY WITH FEDERAL, STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.